Prices and details upon request

Point Loading Test under accelerated test conditions (PLT+)
The PE 100-RC materials described in PAS 1075 are characterized by very high stress crack resistance. The verification of the stress crack resistance of PE 100-RC materials requires an acceleration of the testing procedure.
The PLT under accelerated test conditions (PLT+) was developed by HESSEL Ingenieurtechnik with the aim of accelerating the characterization of the stress crack behavior of PE 100-RC pipes.
The PLT+ is an internationally established testing procedure to demonstrate suitability for alternative installation methods.

Tests according to PAS 1075
Pipes made from Polyethylene for alternative installation techniques - Dimensions, technical requirements and testing

Tests according to DIN EN 12201-1
Plastics piping systems for water supply, and for drainage and sewerage under pressure - Polyethylene (PE) - Part 1: General

Tests according to DIN EN 12201-2
Plastics piping systems for water supply, and for drainage and sewerage under pressure - Polyethylene (PE) - Part 2: Pipes

Tests according to DIN EN 1555-1
Plastics piping systems for the supply of gaseous fuels - Polyethylene (PE) - Part 1: General

Tests according to DIN EN 1555-2
Plastics piping systems for the supply of gaseous fuels - Polyethylene (PE) - Part 2: Pipes
The general decision rule for conformity statements in test reports is as follows:
The conformity statement is: meet the requirement or not meet the requirement.
The requirement was evaluated based on a one-sided confidence level of 97.5%.
Specific risk is used for risk evaluation (w = 0, AL = TL).
Note:
Decision rules contained in applicable standards or specified by the customer take precedence over this general rule.